C-PiPe® 120 DW
Details
A: Steel pipe
B: Fusion Bonded Epoxy (if required)
C: Thermal barrier
D: Insulation layer
Product description
- Steel inner pipe without AC Coating (FBE optional)
- Installable by reeling or S-lay
- Two-layer insulation of Flexilon RS-3173 and RS-3060 cast alloy insulation
- Insulation thickness 15 to 100 mm
- U-value between 2.0 - 15.0 W/m2K
- Lambda value 0.186 W/mK
- Operation temperature up to 120°C (135°C in test)
- System can be used at any water depth
- Anode protection system (when required)
Application process
1
Steel pipe pre-heating Blast cleaning and dust remova
2
Insertion of steel pipe in the mold
3
Closing of the heated mould
4
Application of the 1st layer - thermal barrier
5
Checking the rst layer and moving to the second mold
6
Application of the insulation layer
7
Opening of the mould and pipe release
8
Pipe inspection ready for dispatch
Coating system - main features
- LOGSTOR C-PiPe system uses the Rosehill polymer alloys combining the processing advantages and toughness of polyurethanes with the temperature resistance and adhesion of epoxies in one single application
- The system offers high insulation performance comparable to multi layer PP systems
- It can be installed using all pipe-laying methods, including reeling
- The insulation is moulded to the pipe ensuring fast production process with precise thickness tolerance
- Cutback shape tailored to the exact field joints requirements
- The same material is used on the field joint and the bends, fittings etc. eliminating all interface issues and ensuring end-to-end protection
- Our plant is designed to be mobile, and can be set-up at any relevant project location
Plan capabilities
- Pipe diameter 6’’ to 24’’ (168 mm to 610 mm)
- Mould customized to the pipe lengths including double joints 24.4 m (80 ft)
- Pipe weight up to 20 tons
- Minimum operating service temperature -20°C
- Maximum operating service temperature +95°C